Parts & Tools

The parts division handles the procurement, inventory management and fulfillment, of over 30,000 parts worldwide including both old and new systems. Currently supporting legacy equipment for up to 20 years with spare parts as original or upgraded where applicable. The parts are organized through two 20-foot retrieval systems that expedite delivery to the end user while maximizing storage space.

O-Ring Kit

O-Ring Kit ASEA000001-AA00

Array of O-Ring sizes that are commonly used on a Quantum Stabilizing System. Be prepared! Great for troubleshooting and often a quick solution.


Quantum Stabilizers-torque wrench to adjust tapered pins

Torque Wrench  ATOL000003-AA00

Quantum’s tapered cylinder pins empower the engineer to reduce bearing noise by adjusting bearing compression. Performing this adjustment requires close attention to the applied torque. This wrench covers the full span of torques specified in the Quantum tapered pin adjustment procedure and provides visual indication of the applied torque via the dial gauge. The torque wrench is supplied with a calibration certificate; re-calibration is recommended once a year.


Quantum Accumulator and Suppressor Charging Kit ACCUMULATOR AND SUPPRESSOR CHARGING KIT ASUP000001-3A

Hydraulic accumulators and noise suppressors, components in every Quantum stabilizer system hydraulic power system, need their charge pressure maintained according to the procedures and specifications contained in each individual system manual. Quantum stabilizer systems, both new-build and retrofit, include a charging kit in the original supply. The complete and updated charging kit is now available with everything pictured: case, charging tool, charge checking tool, charging adapters, and Leak-Tec. Each tool or adapter is also available separately, and there is also a video tutorial.


Quantum Charge Checking ToolCHARGE CHECKING TOOL QMSUP23011

The new charge checking tool reduces the pressure drop encountered when using the long hose in the charging tool to check nitrogen pressure. If you find that checking the suppressor charge with your Quantum-supplied charging kit usually results in having to charge the suppressor, the charge checking tool can alleviate the issue.


Quantum Charging AdaptersCHARGING ADAPTERS

The Quantum charging tool comes with the American-style (CGA-580) gas bottle adapter pre-installed. For connection to European style gas bottles, Quantum now offers the English-style (BS-341) gas bottle adapter (pictured left top, Quantum number QMSUP23017) and the German-style (DIN-477) gas bottle adapter (pictured left bottom, Quantum number QMSUP23016).


Quantum Leak-Tec LEAK-TEC QMLIQ00013

As any gas leakage can have a significant effect on suppressor performance Quantum now offers Leak-Tec (pictured) to provide a visual indication of system integrity and to insure that charging valves close completely. Simply apply Leak-Tec and look for bubbles.


Quantum Leak-Tec Hydraulic Power Unit Suction Strainer Wrench

Maintenance on Quantum Hydraulic Power Units for the stabilizer systems can require cleaning or replacing the strainers on the suction side of the hydraulic system.  Quantum designed low-profile wrenches enable removing and installing cleaned or replacement suction strainers without damaging the strainer mesh. The wrench size is specific to the size strainer: QMSTR40010 (.5″ strainers), QMSTR40009 (.75″ strainers), and QMSTR40002 (1.0″ strainers).


Quantum Fuse Kit Fuse Kit AELE000001-AA00

The fuse kit is a small compact kit containing all of the fuses used in a majority of Quantum stabilizer systems. The kit is compact, capable of fitting in a pant pocket. It also includes a watertight case with a small lanyard hole, making it easy to keep near the stabilizer equipment, in case a fuse blows.


Quantum Service GREASE GUN AGR0001000

One of the most important Quantum stabilizer system maintenance procedures is regular greasing. While all Quantum systems require grease, the access points and procedure might differ depending on the system, so please consult your manual for the proper grease type, grease points, pressures and procedures. The grease gun is recommended to insure that the specified, essential pressure is reached and maintained.